Coaxial antenna cable Cellflex 1+5/8 inch
price/meter
Characteristics:
Inner conductor
Material corrugated copper tube
Diameter (mm) 17.7
Dielectric
Material gas-injected cellular polyethylene
Diameter (mm) 43.0
Outer conductor
Material corrugated copper tube
Diameter (mm) 46.6
Jacket
Material black polyethylene
Thickness (mm) 1.7
Diameter (mm) 50.0
Characteristic impedance (?) 50 ±1
Nominal capacity (pF/m) 75
Relative propagation velocity (%) 89
Inductance (?H/m) 0.187
DC-resistance at 20 °C
- inner conductor (?/km) 1.44
- outer conductor (?/km) 0.5
RF peak voltage (kV) 5.5
RF peak power (kW) 302
Cut-off-frequency (GHz) 2.8
Insulation resistance (M?.km) >>5000
Minimum bending radius
a) single bending (cm) 20
b) 15 repeated bends (cm) 40
Maximum pulling strength (daN) 250
Recommended temperature range
- Storage -70 to +85 °C
- Installation -40 to +60 °C
- Operation -55 to +85 °C
Maximum length per hoisting grip (m) 70
Maximum hanger spacing (m) 1.5
Flat plate crush resistance (kg/mm) 2.4
Bending moment (Nm) 38
Approximate weight[2] (kg/km) 1019 / 1131
[1] a = 0.064
b = 0.000253
?(?) = a . ? f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket
[3] Nominal values
[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
price/meter
Characteristics:
Inner conductor
Material corrugated copper tube
Diameter (mm) 17.7
Dielectric
Material gas-injected cellular polyethylene
Diameter (mm) 43.0
Outer conductor
Material corrugated copper tube
Diameter (mm) 46.6
Jacket
Material black polyethylene
Thickness (mm) 1.7
Diameter (mm) 50.0
Characteristic impedance (?) 50 ±1
Nominal capacity (pF/m) 75
Relative propagation velocity (%) 89
Inductance (?H/m) 0.187
DC-resistance at 20 °C
- inner conductor (?/km) 1.44
- outer conductor (?/km) 0.5
RF peak voltage (kV) 5.5
RF peak power (kW) 302
Cut-off-frequency (GHz) 2.8
Insulation resistance (M?.km) >>5000
Minimum bending radius
a) single bending (cm) 20
b) 15 repeated bends (cm) 40
Maximum pulling strength (daN) 250
Recommended temperature range
- Storage -70 to +85 °C
- Installation -40 to +60 °C
- Operation -55 to +85 °C
Maximum length per hoisting grip (m) 70
Maximum hanger spacing (m) 1.5
Flat plate crush resistance (kg/mm) 2.4
Bending moment (Nm) 38
Approximate weight[2] (kg/km) 1019 / 1131
[1] a = 0.064
b = 0.000253
?(?) = a . ? f + b . f [dB/100m]
[2] Standard PE jacket / HLFR jacket
[3] Nominal values
[4] Ambient temperature = 40 °C; Temperature of inner conductor = 100 °C;
VSWR = 1.0; no solar loading
Kunden, die dieses Produkt gekauft haben, haben auch gekauft